Worked examples
Three traced cases: heat-recovery water preheating, thermal storage and solar feasibility. Every number can be reproduced with a calculator or spreadsheet.
Inputs are example values, not project data. The purpose is to let an engineer reproduce each step, not to suggest these results apply to any hospital. Results are screening-level and the models have not been independently engineering-reviewed.
Heat-recovery water preheater with a manufacturer map (case H4)
Room air 83 °F and 125 °F target are interpolated on a 3×3 manufacturer grid (bilinear, no extrapolation). Heat to water is limited by demand, by source heat, or by unit capacity, whichever is smallest.
Inputs
| Field | Value |
|---|---|
| rec | 60 |
| hrs | 6000 |
| cap | 50 |
| troom | 83 |
| cop0 | 3.0 |
| dcop | 0.3 |
| rlift | 65 |
| dlift | 0.25 |
| gpd | 3000 |
| tin | 60 |
| tout | 125 |
| days | 365 |
| eff | 80 |
| gp | 1.2 |
| ep | 0.12 |
| kwt | 0.9 |
| coin | 100 |
| ef | 0.348 |
| cpx | 60000 |
| om | 1000 |
| copTab | 70,110,30,10 | 70,130,28,11 | 70,150,25,12 | 90,110,36,10.5 | 90,130,34,11.5 | 90,150,31,12.5 | 110,110,42,11 | 110,130,40,12 | 110,150,37,13 |
Hand calculation versus calculator
| Quantity | Equation | Independent | Calculator |
|---|---|---|---|
| COP at the operating point | bilinear capacity / bilinear input | 2.92551 | 2.92551 |
| Hot-water heat demand (kWh/yr) | gal/day x 8.34 x dT / 3,412.142 x days | 173,967 | 173,967 |
| Recoverable source heat (kWh/yr) | kW x hours x capture % | 180,000 | 180000 |
| Heat delivered (kWh/yr) | min(demand, source x COP/(COP-1), capacity x hours) | 173,967 | 173,967 |
| Electricity (kWh/yr) | heat / COP | 59,465.5 | 59,465.5 |
| Heat taken from room air (kWh/yr) | heat - electricity | 114,501 | 114,501 |
| Gas displaced (therms/yr) | heat x 3.412141633 / 100 / boiler efficiency | 7,419.99 | 7,419.99 |
| Net annual benefit | gas saved + cooling credit - electricity - O&M | 4,284.38 | 4,284.38 |
Energy balance check: heat delivered = heat from room air + electrical input. Here demand is the smallest of the three limits, so cover is 100%; reduce the gal/day or enter fewer heat-recovery hours to see the source or unit capacity limit instead.
Thermal storage with a 500-ton outage reserve (case T6)
Shifts half of a 1,500-ton, 6-hour on-peak load. Charging capacity available = (installed - reserve) x (1 - derate) - concurrent load.
Inputs
| Field | Value |
|---|---|
| tons | 1500 |
| hrs | 6 |
| shift | 50 |
| days | 150 |
| kwt | 0.75 |
| kwi | 1.0 |
| loss | 5 |
| aux | 60 |
| chg | 8 |
| pOn | 0.18 |
| pOff | 0.07 |
| dem | 15 |
| dem2 | 0 |
| dmo | 5 |
| efOn | 0.4 |
| efOff | 0.34 |
| cpx | 150 |
| om | 15000 |
| ft3 | 3 |
| capInst | 2500 |
| capLoad | 900 |
| derate | 30 |
| dcr | 80 |
| pvShare | 0 |
| pvVal | 0.04 |
| dayP | 0.1 |
| efDay | 0.3 |
| pen | 10 |
| red | 500 |
Hand calculation versus calculator
| Quantity | Equation | Independent | Calculator |
|---|---|---|---|
| Shifted energy (ton-h/day) | tons x hours x share | 4,500 | 4500 |
| Storage to charge (ton-h) | shifted / (1 - loss) | 4,736.84 | 4,736.84 |
| Charging load needed (tons) | charge ton-h / charging hours | 592.105 | 592.105 |
| Charging capacity available (tons) | (installed - reserve) x (1 - derate) - concurrent | 500 | 500 |
| Energy bill saving ($/yr) | (on-peak avoided - off-peak charging - auxiliary) x days | 26,628.2 | 26,628.2 |
| Net annual benefit ($/yr) | energy + demand credit - penalty - O&M | 41,778.2 | 41,778.2 |
Charging needs more tons than are available once the reserve is held back, so the tool reports the design as not feasible as entered and gives no payback, even though the bill arithmetic is positive.
Solar feasibility with inverter replacement and residual value (case S4)
Roof and canopy arrays with year-12 inverter replacement, residual value at the end, real discount rate and escalation.
Inputs
| Field | Value |
|---|---|
| roofA | 120000 |
| roofU | 45 |
| roofD | 11 |
| canA | 60000 |
| canD | 15 |
| yld | 1500 |
| deg | 0.5 |
| life | 25 |
| ilr | 1.25 |
| sun | 10 |
| dayMwh | 12300 |
| minKw | 1800 |
| load | 22350 |
| retail | 0.12 |
| expOk | 1 |
| expRate | 0.04 |
| cost | 1.9 |
| om | 18 |
| extra | 150000 |
| ef | 0.348 |
| invYr | 12 |
| invCost | 90 |
| resid | 150000 |
| disc | 5 |
| esc | 2 |
Hand calculation versus calculator
| Quantity | Equation | Independent | Calculator |
|---|---|---|---|
| Array size (kWdc) | roof area x usable % x W/ft2 + canopy area x W/ft2 | 1,494 | 1494 |
| Year-1 generation (kWh) | kWdc x specific yield | 2.241e+06 | 2241000 |
| Year-1 on-site use (kWh) | 15-min half-sine day vs flat solar-hour load, clipped at inverter AC | 2.241e+06 | 2241000 |
| Capital cost ($) | roof + canopy + extras | 2.9886e+06 | 2988600 |
| Annual O&M ($) | kWdc x $/kWdc-yr | 26,892 | 26892 |
| Net present value ($) | sum of discounted net cash + residual - first cost | 1.00367e+06 | 1.00367e+06 |
| Internal rate of return (%) | rate where NPV = 0 (bisection) | 7.86051 | 7.86051 |
| Discounted payback (year) | first year cumulative discounted cash >= 0 | 17 | 17 |
The same inputs run in an external spreadsheet should reproduce the NPV to within rounding.