Playbooks
Four workstreams, in the order most hospitals should tackle them. Each assumes clinical operations and life safety come first.
Safety boundary. Do not change pressure relationships, air change rates, medical gas, or critical power without review by your qualified engineers, infection prevention and the applicable codes, for example NFPA 99, NFPA 110 and ASHRAE 170.
Measure before you cut
- Set the boundary and baseline: twelve months of data, weather-normalised, by building and by system.
- Count Scope 1 and 2 using the GHG Protocol. Include refrigerant top-ups, anesthetic gas purchases, nitrous oxide, diesel and gas.
- Sub-meter the big loads: chillers, pumps, air handling units, steam or hot water, operating theatres, imaging, medical gas compressors.
- Run an ASHRAE Level 2 audit, then adopt an energy management system such as ISO 50001 so savings survive staff changes.
- Report to one KPI set: kWh per m² per year, kWh per occupied bed-day, tCO₂e per m².
Chilled water and air systems
- Sequence chillers on measured plant kW/ton, not on habit. Trim and respond chilled water supply temperature and condenser water resets.
- Fit or tune VFDs on pumps and fans, and remove throttling valves that waste the saving.
- Schedule and set back air handlers in non-critical areas using occupancy data. Leave pressure-controlled areas such as isolation rooms, pharmacy compounding and operating theatres to a documented, reviewed strategy.
- Fix control faults first: simultaneous heating and cooling, stuck dampers, failed sensors, overridden schedules. These are cheap and large.
- Use your BMS trend logs to prove each change, and keep a rollback path.
Anesthetic gases, nitrous oxide and refrigerants
- Inventory purchases of inhaled anesthetics. Desflurane has a far higher global warming potential than sevoflurane or isoflurane, so agent choice is a clinical decision with a large emissions effect. Involve anesthesiology leadership.
- Audit piped nitrous oxide for leaks, including manifolds and pipework, and decommission unused piped supply where clinically agreed.
- Keep a refrigerant register by asset: type, charge, top-ups, leak checks. Plan for the HFC phase-down under the Kigali Amendment when replacing plant.
- Prefer lower-GWP refrigerants and sealed systems at replacement, within the equipment manufacturer's and safety-code requirements.
Clean supply and resilience
- Reduce demand first so solar and storage are sized for a smaller load.
- Design PV and battery storage together with the critical power architecture. Storage can support resilience, but it does not replace code-required emergency power unless the design and authority having jurisdiction accept it.
- Check grid connection limits, protection settings and export rules early. They set the real constraint on size.
- Compare options on lifecycle cost: NPV, IRR and simple payback with the same assumptions, and include maintenance, degradation and tariff changes.
- Contract clean power where on-site generation is limited, and prefer additional capacity over unbundled certificates where possible.