Hospital Net Zero

Utility M&V project tracker

Calculate avoided energy against an adjusted baseline and keep measured and estimated savings separate.

Browser-only. These tools run in your browser. Nothing is sent to a server. Do not enter patient identifiers, confidential system layouts, facility vulnerabilities, credentials, security information or personal data, even if you choose to save locally. Saved entries are stored unencrypted in this browser, so do not save on a shared computer. Use generic names or codes you are comfortable keeping on this device. Educational and screening material only. It supports qualified professional judgment and does not determine code compliance, replace your hospital's policies or the advice of qualified engineers, clinicians and infection-prevention staff.

← All resilience tools

Utility M&V project trackerScreening record

Evidence classification. The Basis and IPMVP option you pick are your own labels. This tool cannot verify meters, model fit or method conformity, so no result here is an independently verified saving. Rows with an invalid baseline (for example a negative predicted baseline) are rejected. Record the baseline and reporting periods, the data source and the reason for any adjustment.

Baseline model per project: predicted baseline = intercept + slope x driver (for example degree-days). Avoided energy = predicted baseline + non-routine adjustment - measured reporting-period energy. Mark each saving measured or estimated; the totals keep them apart.

Results